MPM-906 MultiParametere Patient Monitor

Patient Monitor New Type – My Life MPM 906N

Rated 2.00 out of 5 based on 1 customer rating
(1 customer review)

SKU: MPM-906N Category: Tags: ,

Description

Multi Parameter Patient Monitor – MPM 906 New Type

FEATURES

  • 1” LCD displey high resolution (1024×768)
  • Large number display for longe distance vision
  • Nellcor digital SPO2 technologi offer anti- motion and

anti-low perfusion function

  • 168 hours tabular and grapich trends and data storage
  • Up to 66 beds netwoork capacity , to connect with HIS

 

 

Technical Specification

  • Safety: IEC60601 (GB9706)
  • Dimension : 340mm(W) x 270mm(H)x215mm(D)
  • Power Supply : 90-280V AC50Hz/60Hz
  • Alarm Indication : Visual and audible alarm
  • 1000 Groups of alarm events review
  • Application : Adult, pediatric and neonate

 

ECG

  • Leads : I, II, III,aVR, aVL,aVf,V
  • Gains : 2.5mm/mv,5mm/mv,10mm/mv,20mm/mv,40mm/mv,auto
  • Input Impedence : >5MΩ
  • Common Mode Rejection Ratio : >100 dB
  • Bandwith : 0.5-40Hz (monitoring mode)

0.05-120Hz (diagnostic mode)

1-25Hz (surgicacl mode)

  • Protection : Segregation break down voltage 4000VAC, 50/60Hz,

Resistant to high- frequency electro tome, myoelectricity, AC, drifting interference

  • Indication of Detachment of electrodes : Available
  • Playback of Cardiogram : Available
  • Scanning Speed : 12.5mm/s, 25mm/s,50mm/s
  • Heart Rate Range : 0-300BPM
  • Accuracy : ± 1BPM

 

NIBP

  • Method : Automatic oscilometric
  • Operation Modes : Single (manual), Cycle (automatic),rapid (continous)
  • Measurment : Systolic pressure/diastolic pressure/ mean
  • Range : Adult : 0-300mmHg

Pediatric : 0-235mmHg

Neonate : 0-135 mmHg

  • Unit : mmHg/Kpa selectable
  • Auto measurement : 1,2,3,4,5,10,15,20,30,45,60,90 minutes,2,4,8,12 hours
  • 750 groups of NIBP measuring data review

 

 

RESP

  • Methode : Impedance Measurement
  • Measuring Range : 0-180 bpm (max. 180 bpm)
  • Alarm Limit : 0-180 bpm, upper and lower limit continuosly adjustable
  • Apnea alarm : Available

 

SPO2(Pulse Oximetri)

  • Digital SPO2 technologi
  • Range : 0-100%
  • Accuracyni : ±2% (70-100%),±3% (35-69%)
  • Range of Pulse Rate : 20-250BPM ±1BPM

 

TEMP
  • Channel : 2 channel (OPTIONAL)
  • Range : 0-50°C
  • Unit : Celsius, Fahrenheit
  • Resolution : 1mmHg
  • Accuracy : ± 0.1°C
  • Alarm Range : 0-50°C

 

IBP (OPTIONAL)
  • Channel : 2 channels
  • Range : -50-300mmHg
  • Resolution : 1mmHg
  • Accuracy : ±1mmHg (±1%) without probe

± 4mmHg(±2%) with probe

  • Unit : mmHg, Kpa
  • Converter Sensitivity : 5µV/V/mmHg
  • Names of Pressures : ART/PA/CVP/LAP/RAP/ICP

 

EtCO2 (side stream) (OPTIONAL)

  • Method : Side stream
  • Range : 0.0-13.1%
  • Resolution : 0,1mmHg (0.01%)
  • Accuracy : <5% Etco2,± 0,3%

>5% Etco2, <10%

 

Standard configuration

  • ECG, HR, RESP, SPO2, PR, TEMP, Battery

 

OPTION

2-TEMP, 2-IBP, Recorder, EtCo2 (side stream,main stream), Multi-gas analysis/O2, Nellcor SPO2

 